Abstract

The accuracy in making Magnetic Sensitivity measurements of an integrated three-dimension Hall sensor can in general be very challenging. Sensitivity measurements are typically performed using an integrated coil system, which allows the generation of a low strength magnetic field. When the required field strength is greater than a few hundreds microTesla an external magnetic field source is needed. A new Test Hardware concept is presented to allow the calibration and test over temperature of a 3D hall integrated device. Calibration is performed by a direct measurement of the Sensitivity pre-trim of the three X, Y and Z sensors. The new test hardware gives the possibility to generate a stable and homogenous magnetic field and allows the test of the magnetic performances for any part in the production environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.