Abstract

The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.

Highlights

  • The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas

  • This study aimed to evaluate the sensitivity and specificity of the point-of-care circulating cathodic antigen (POC-cathodic antigen (CCA)) assay and the morbidity of schistosomiasis in a low-endemic area in Brazil

  • Results of the POC-CCA urine assay were blindly scored by two investigators as either negative or positive and read as either strong or weak responses

Read more

Summary

Introduction

The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. Investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Results: The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. The sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Conclusions: Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a lowendemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas. Dense bands of fibrosis around the portal tracts are typical of schistosomiasis[4,5]

Objectives
Methods
Results
Conclusion