Abstract
Rapid Diagnostic Tests (RDT) are useful to identify syphilis cases, particularly for hard-to-reach populations and if laboratory services are scarce. However, RDT performance may be suboptimal. We aimed to assess the sensitivity and specificity of a syphilis RDT using well-characterized blood donors’ samples. We categorized samples from 811 blood donors into five groups: 1 - Samples with reactive Chemiluminescence (QML), FTA-Abs, and VDRL; 2 - Samples with reactive QML and FTA-Abs, and nonreactive VDRL; 3 - Samples with reactive QML, and nonreactive for other markers (false-positives); 4 - Controls with nonreactive QML; and 5 - Samples reactive for HIV, with nonreactive QML. Sensitivity was tested in groups 1 (overall and according to VDRL titers) and 2; specificity was tested in groups 3‒5. The RDT had high specificity, even in samples reactive for HIV. The sensitivity was high (91.9%) in samples with reactive VDRL but varied between 75.0%‒100% according to VDRL titers. The overall sensitivity was lower (81.3%) in samples with reactive FTA-Abs and nonreactive VDRL. The RDT is a useful tool to detect active syphilis but may be more limited for cases with very early or remote infection, or those with prior treatment. When higher sensitivity is needed, additional strategies including recurrent testing or laboratory-based tests may be required.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.