Abstract

Seen from an international perspective preinsulated bonded pipe systems dominate in heat distribution. These pipe systems are usually buried in sand and soil-pipe interaction hinders thermal strains, which make economic solutions for bow- and T-sections possible. For static design pipe-soil interaction must be known as accurate as possible. However, several parameters are influencing the quantity of the expected soil reaction. Main influencing factors are dependent on the used bedding material and geometry. Furthermore current research results made additional soil-phenomena evident, which are hardening effects and stress redistribution during operation. A new calculation approach for the axial soil reaction was developed in 2015 based on existing test results and numerical simulations. A sensitivity analyses were carried out to estimate the significance of relevant parameters and the existing calculation approaches. This paper identifies the significant parameters and suggests parameter sets for lowest and highest axial soil reaction. Two main boundary situations are taken into account a) first movement b) during operation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.