Abstract
In this paper, a sensitivity analysis of a non-symmetrical resonant converter for battery charging is presented. The effects of the resonant tank parameters on the output power and the control variables is examined through sensitivity analysis. Pulse frequency modulation (PFM) and phase-shift modulation (PSM) techniques are implemented to control the converter output. A sensitivity analysis is conducted for the whole frequency spectrum and different operation conditions. The sensitivity coefficients of the output power and the control variables are calculated with respect to crucial parameters of the resonant tank. An experimental prototype is implemented to verify the sensitivity analysis and the control method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.