Abstract

A method for nucleic acid amplification, loop-mediated isothermal amplification (LAMP) is a novel, sensitive and rapid technique, which can be applied for disease diagnosis in aquaculture. Using the LAMP method, a highly specific and sensitive diagnostic system for infectious hypodermal and hematopoietic necrosis virus (IHHNV) detection was designed. A set of four primers was designed by targeting the IHHNV genome DNA. By the detection system, target DNA was amplified and visualized on agarose gel within 60 min under isothermal condition at 64 °C. Without gel electrophoresis, the LAMP amplicon was visualized directly in the reaction tube by addition of SYBR Green I for a naked-eye inspection. The LAMP reaction was also assessed by the white turbidity of magnesium pyrophosphate (a by-product of LAMP) in the tube. The assay had a detection limit of 5–500 copies of DNA template with gel electrophoresis, SYBR Green I and white turbidity with naked-eye inspection. The detection sensitivity of LAMP was 100-fold higher than the PCR. A diagnostic procedure which is rapid and highly sensitive was developed for IHHNV detection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call