Abstract
The tables of the mean restricted collision mass stopping power ratios for water, polystyrene and acrylic relative to air given in the AAPM TG‐21 protocol have been fitted to an expression with 20 coefficients using the depth in the phantom and the mean incident electron energy as two independent variables. Using these expressions, the calculated values agree with the tabulated values within +0.5% in 85% of the cases and within ±1.0% in 95% of the cases. For each of the four cylindrical chamber inner diameters, given in the protocol, the electron fluence correction Prepl has been fitted to an expression with four coefficients using the mean electron energy at depth z as an independent variable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.