Abstract

Abstract Semi-active control methods, where coefficient of viscous damping or spring constant are changed effectively according to the state of control object, have received much attention from control performance and energy consumption. This study deals with the application of semi-active control method to base isolation control. Semi-active damper is classified into a bilinear system which belongs to a nonlinear system. The bilinear optimal control theory using feedforward control of disturbance is applied to a base isolation control problem of building structure. The variable damper used in this study is a discrete type of coefficient and it takes delay to switch the coefficient. By taking account of these characteristics, the control performance is investigated in the numerical calculation. As a result, it was shown that the method has high control performance in a wide frequency range, and it is effective for the vibration base isolation of building structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.