Abstract

Buildup factor of gamma and X-ray photons in the energy range of 0.2-2 MeV in water and soft tissue is computed using Monte Carlo code MCNP4C. The results are compared with the buildup factor data of pure water. A new relationship estimating buildup factor as a function of penetration depth, Compton scattering and energy absorption cross sections is introduced. The new relationship estimates buildup factor with 5 % deviation compared with the existing data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.