Abstract

Low-energy electron irradiation of complementary metal-oxide semiconductor (CMOS) devices has been correlated to cobalt-60 gamma irradiation in terms of oxide space charges and interface states. <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sup> This paper reports on the results obtained using the low-energy electron beam of a standard commercial scanning-electron-microscope (SEM) for in-process hardness assurance screening and as a tool for rapid evaluation of process variations designed to improve total-dose radiation hardness. The techniques for SEM testing are described, and the results of correlation studies of radiation effects produced by the SEM, gamma radiation (Co-60), and 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sup> -eV sources compared. The variance in total dose radiation hardness over a single wafer and from wafer to wafer has been investigated for the CMOS CD-4007 array and the results are reported.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.