Abstract

A hybrid siloxane-based coating was modified with CeO2 nanoparticles and applied on AZ31. The corrosion protection performance was evaluated via Electrochemical Impedance Spectroscopy (EIS) in 0.05 M NaCl. CeO2-modified coating showed improved and more stable protective performance compared to the blank coating. Localized healing of the modified coating was studied via Scanning Vibrating Electrode Technique (SVET), Scanning Ion-Selective Electrode Technique (SIET) and Localized Electrochemical Impedance Spectroscopy (LEIS). Addition of ceria led to lower cathodic activity in 0.05 M NaCl and alkalization was kept localized. The CeO2-modified coating provided corrosion protection, including pre-emptive healing of localized corrosion activity, of AZ31.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call