Abstract

This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.