Abstract

BackgroundEfficient ampullary intervention is essential for endoscopic retrograde cholangiopancreatography (ERCP) in patients with a prior Billroth II gastrectomy. We retrospectively evaluated the safety and effectiveness of ampullary intervention using fully covered self-expandable metal stents (FCSEMSs) for the management of common bile duct (CBD) stones in a subset of patients with a history of Billroth II gastrectomy. MethodsThis retrospective analysis involved patients with a prior Billroth II gastrectomy who underwent ampullary intervention with FCSEMSs for the management of CBD stones. The factors associated with FCSEMSs placement, treatment success, and procedural complications were analyzed. ResultsA group of 15 patients (10 males; median age, 78 years) underwent biliary metal stent placement for high degree of CBD angulation (6), small or flat papilla with unclear margin (5), current use of double antiplatelet agents or an anticoagulant (2), unwanted instrumentation of the cystic duct (1), and insecure position of the scope (1). Ampullary intervention with FCSEMSs was successful in all patients. After dilating the ampulla of Vater and building a durable conduit with FCSEMSs immediately, CBD stones were removed successfully from all patients in a single session. A mild post-ERCP pancreatitis occurred in one patient, who recovered without complications. ConclusionAmpullary intervention with FCSEMSs is safe and effective for the management of CBD stones in a subset of patients with a history of Billroth II gastrectomy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call