Abstract
This study proposes a novel model-based automatic search algorithm to realize the self-calibration of nonlinear signal model for angular position sensors. In some high-precision angular position sensors, nonlinearity of the signal model is the main source of errors and cannot be handled effectively. By constructing a signal flow network framework and by embedding a modeling search network, the parameters of the nonlinear signal model can be searched, and the calibration signal can be obtained. The convergence of the network search process was analyzed. The relationship between the optimization threshold and the convergence accuracy was also studied in simulations. Compared with the maximum angular error reduction to 47.42% after the calibration with simplified model that ignores signal nonlinearities, the proposed scheme was able to reduce this error to 0.0025% in simulations. By implementing the technique in a capacitive angular position sensor, the experimental results showed that the maximum angular error was reduced to 1.63% compared to a reduction of 86.02% achieved with the simplified model calibration. The effects of the search network order and layer number on the calibration accuracy were also analyzed, and the optimal parameters under experimental conditions were obtained. Correspondingly, the proposed scheme is able to handle calibration of nonlinear signal model and further improve sensor accuracy.
Highlights
Angular position information is important in many control and inspection systems
The capacitive angular position sensors (CAPS) was mounted on a turntable which rotated at 0.5 °/s
The CAPS was mounted on a turntable which rotated at 0.5 ◦ /s
Summary
Angular position information is important in many control and inspection systems. In application scenarios, such as in unmanned aerial vehicles and industrial robots, obtaining accurate angular information is crucial. Angular position sensors such as resolvers [1,2] and capacitive angular position sensors (CAPS) are driven by excitation voltages [3,4]. The angular position information is determined by a set of orthogonal sine and cosine signals. The output signals usually contain amplitude deviations, direct-current (DC) offsets, phase shifts, and other nonlinear disturbances which are difficult to handle.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.