Abstract
Accurate detection and timely care for patients with high myopia present significant challenges. We developed a deep learning (DL) system enhanced by a self-supervised learning (SSL) approach to improve the automatic diagnosis of myopic maculopathy (MM). Using a dataset of 7,906 images from the Shanghai High Myopia Screening Project and a public validation set of 1,391 images from MMAC2023, our method significantly outperformed conventional techniques. Internally, it achieved 96.8% accuracy, 83.1% sensitivity, and 95.6% specificity, with AUC values of 0.982 and 0.999. Externally, it maintained 89.0% accuracy, 71.7% sensitivity, and 87.8% specificity, with AUC values of 0.978 and 0.973. The model's Cohen's kappa values exceeded 0.8, indicating substantial agreement with retinal experts. Our SSL-enhanced DL approach offers high accuracy and potential to enhance large-scale myopia screenings, demonstrating broader significance in improving early detection and treatment of MM.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.