Abstract
Backgrounds and Objectives: Thoracic endovascular aortic repair (TEVAR) has currently become the “first-line choice” for descending aortic pathologies. For pathologies located at the aortic arch, TEVAR with physician-modified fenestration (PMF) has been gained popularity as an alternative choice. However, stent fenestration is an experience-dependent technique and comes with possible adverse events such as misalignment. This study aims to introduce the self-radiopaque PMF (SF), which uses the radiopaque marker as a guiding indicator.Methods: This is a single-center retrospective study of 125 patients who underwent the SF-TEVAR in Second Xiangya Hospital from December 2015 to December 2020. Data include basic clinical information and technique records of SF-TEVAR with follow-up results.Results: According to the SF-TEVAR protocol, we have performed the procedures on 125 patients and obtained an instant success rate of 98.4%. A total of 140 aortic stent-grafts and 44 bridging stents have been implanted in this study. The operation time is 64.6 ± 19.3 min, X-ray exposure time (from first digital subtraction angiography (DSA) to last DSA) is 25.6 ± 14.3 min, and contrast volume is 82.2 ± 22.6 ml. The success rate of PMF alignment is 98.4%. One bailout stent-graft was implanted into the left subclavian artery (LSA) by the chimney technique (0.8%). One fenestration was successfully and immediately corrected after misalignment (0.8%). Large simultaneous fenestration was performed in six patients (4.8%) for the left common carotid artery (LCCA) and LSA and in two patients (1.6%) for IA, LCCA, and LSA. One hundred twenty-two out of 125 patients' LSAs have been kept patent by the technique during the follow-up. The bridging stent group consists of 44 patients who received LSA stents, while the non-bridging stent group includes the other 81 patients. Type I endoleak has occurred in seven patients (5.6%) 1 week after the procedure. During follow-up (23 ± 18 months), survival rate is 95.7% and branch artery patent rate is 97.4%.Conclusions: The SF-TEVAR technique, which utilizes the radiopaque marker in stent-graft as an indication for PMF in TEVAR, seems a likely safe, effective, and efficient procedure that brings acceptable survival rate and branch artery patency rate. SF-TEVAR serves as a progressive alternative method to keep the branch artery patent in aortic arch endovascular reconstruction.
Highlights
Reviewed by: Juan Bustamante Munguira, Hospital Clínico Universitario de Valladolid, Spain Maruti Haranal, National Heart Institute, Malaysia
self-radiopaque PMF (SF)-Thoracic endovascular aortic repair (TEVAR) serves as a progressive alternative method to keep the branch artery patent in aortic arch endovascular reconstruction
With the rapid development of thoracic endovascular aortic repair (TEVAR) technique and device, the indications of TEVAR are assumed to expand to aortic arch [1, 2]
Summary
Reviewed by: Juan Bustamante Munguira, Hospital Clínico Universitario de Valladolid, Spain Maruti Haranal, National Heart Institute, Malaysia. Backgrounds and Objectives: Thoracic endovascular aortic repair (TEVAR) has currently become the “first-line choice” for descending aortic pathologies. For pathologies located at the aortic arch, TEVAR with physician-modified fenestration (PMF) has been gained popularity as an alternative choice. Stent fenestration is an experience-dependent technique and comes with possible adverse events such as misalignment. This study aims to introduce the self-radiopaque PMF (SF), which uses the radiopaque marker as a guiding indicator
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have