Abstract

Despite increased diabetes device use, few adolescents with type 1 diabetes (T1D) meet glycemic targets. We examine associations between utilization of insulin pumps and continuous glucose monitoring (CGM) and glycemic control. This prospective cohort study included 80 youths (10-18 years of age) with T1D. Multiple linear regression and linear mixed models (LMM) were used to estimate the effects of device self-management on HbA1c and daily time in range (70-180 mg/dL), respectively. Every blood glucose (BG) input/day was associated with a 0.2% decrease in HbA1c (95% CI: -0.297, -0.013), each bolus/day was associated with a 0.2% decrease (-0.327, -0.057), and use of CGM was associated with a 0.5% decrease (-1.00, -0.075). Among CGM users (n = 45) every 10% increase in CGM use was associated with a 0.3% decrease in HbA1c (-0.390, -0.180). In LMM accounting for within subject and between subject variability, there was a negative association between BG input/day frequency (coefficient = -1.880, [-2.640, -1.117]) and time in range. Residual random effects for CGM users were large showing time in range varied between youth with a SD of 15.0% (3 hours and 36 minutes) (SE 2.029, [11.484, 19.530]). Time in range varied significantly from day-to-day with SD of 18.6% (4 hours and 40 minutes) (SE0.455, [17.690, 19.473]). Device self-management behaviors among youth are significantly associated with both HbA1c and time in range. Our findings showing an association between reduced time in range and increased self-management behaviors is novel and deserves further investigation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call