Abstract

The determination of effective excess carrier lifetimes from photoconductance measurements generally requires knowledge of the absolute generation rate within a sample. Measurements of the generation rate typically involve measurement of the sample absorption spectrum and of the incident light intensity. This letter presents an experimental and analytical method by which both the effective lifetime and the generation rate can be self-consistently determined. The method involves only relative measurements of the generation rate, greatly simplifying the experimental requirements. Good agreement is found experimentally between the results achieved using this method and results from transient photoconductance measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.