Abstract
In this letter, we report a strategy of detecting the DNA targets by using a thin layer of self-assembled cholesterol-labeled DNA probes at the liquid crystal (LC)/aqueous interface. When the system is exposed to 51 μg/ml of complementary DNA targets, the optical appearance of LC shows a continuous change from dark to bright under the crossed polars within 15 min. No obvious change can be observed when the system is exposed to one or two base-pair mismatch DNA targets. This system provides a principle for label-free and real-time detection of DNA targets without any fluorescent labeling.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.