A selective fluorimetric method was developed to quantify camptothecin (CPT) in irinotecan (CPT-11) and in topotecan (TPT) based anti-cancer drugs. Selectivity was achieved by experimental optimization and using synchronized scanning and second-order spectral derivatization. The limits of quantification for CPT were in the order of 1 × 10−7 mol L−1 with a linear response up to 1 × 10−5 mol L−1. The combined uncertainty associated with the CPT fluorescence measurement at a 5 × 10−7 mol L−1 level were 10.9% and 6% of the reference level, respectively, for TPT and CPT-11 based pharmaceutical formulations. The CPT recoveries of 95 ± 12% and 91 ± 5.6% (n = 3) were achieved, respectively, in samples containing CPT-11 and TPT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.