Abstract
A novel solid phase extraction (SPE) adsorbent, polyethylene glycol (PEG) immobilized zirconium ion-modified zeolite-imidazole framework (ZIF) molecular-imprinted polymer (ZIF@PEG@Zr@MIPs), was developed for detecting hippuric acid (HA) and 4-methylhippuric acid (4-MHA) in human urine using HPLC-UV. Zirconium ions (Zr4+) anchored on the porous ZIF act as binding sites, facilitating coordination and electrostatic interaction with HA and 4-MHA carboxyl groups. Dopamine (DA) imprinting introduces additional sites, enabling π-π conjugation and hydrogen bonding with HA and 4-MHA, enhancing specific adsorption. The adsorbent, using HA as a template, demonstrated adsorption capacities of 37.98 mg g−1 for HA and 32.99 mg g−1 for 4-MHA. Imprinted factors (IF) were 2.68 for HA and 2.17 for 4-MHA, with a limit of detection (LOD) of 0.015 mg L−1 for HA and 0.011 mg L−1 for 4-MHA. The SPE-HPLC-UV method achieved 84.8–96.2% recovery and 0.3–2.2% relative standard deviation (RSD), illustrating its potential in health monitoring and environmental safety.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.