Abstract
AbstractIn this paper, a novel monolithic stir bar based on molecularly imprinted polymer (MIP) was firstly developed by filling modified neodymium magnet (Nd2Fe14B) powders into a glass tube (60 × 4 mm), followed by the imprinted grafting with bisphenol A (BPA) as the template molecule by thermal polymerization. It has been successfully used for the stir bar sorptive extraction (SBSE) and its extraction performance illustrated that the MIP‐encapsulated stir bar had stronger affinity to the template molecule, compared with the stir bar based on the non‐imprinted molecularly polymer (NIP). Under the optimal extraction conditions, a simple method based on the coupling of MIP‐SBSE with high performance liquid chromatography (HPLC) was used for the selective determination of the model mixtures of BPA, 4‐phenylphenol (PP) and phenol (P) in bottled water. The recoveries of BPA, PP and P were in the range of 88.5‐96.1%, 78.2‐89.7%, 81.3‐89.5% at three spiked levels, respectively, demonstrating that higher extraction and the specific absorption occurred between the template molecule and the prepared MIP stir bar.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of the Chinese Chemical Society
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.