Abstract
Complexation–ultrafiltration process was investigated to separate selectively Hg(II) and Cd(II) from binary metal solutions by using poly (acrylic acid) sodium salt as a complexing agent. Effects of operating parameters on selective separation factors ( β Cd/Hg) of the both metals have been examined in detail. Results indicated that loading rate, pH, concentration of salt added and low-molecular competitive complexing agent affect significantly β Cd/Hg value. Further, a concentration experiment was carried out according to the previous optimum parameters. Rejection coefficient of mercury is close to 1, while that of cadmium is about 0.1. The experiment was characterized by good effectiveness, and enabled the rapid linear increase of mercury concentration and very slow increase of cadmium concentration in the retentate. Then, a diafiltration technique was applied to separate further the both metals. Cadmium concentration in the retentate declines sharply with the diafiltration volume, whereas for mercury it is the contrary.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.