Abstract

Detection of highly ppm range hydrogen concentration in atmospheres contaminated with various volatile organic compounds is in demand for numerous applications. Different devices and techniques have been applied for the problems which are mostly based on utilization of hydrogen permeable membranes. Here, we have used a single generic metal oxide gas sensor for this task. No filter or membrane is utilized. The operating temperature of the sensor is modulated with a voltage waveform specifically designed for producing step-like temperature changes on the oxide pallet. By applying four different step-like temperature jumps, each of 1s duration, the sensor produces response patterns which are processed with common pattern recognition techniques. The technique was examined by its practical use for the ~10 ppm (volume) hydrogen measurement in a background containing ~1000 ppm ethanol. The analysis takes only 4s, and the obtained patterns are reproducible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.