Abstract

The Selective Harmonic Elimination (SHE) for 3-Phase Voltage Source Inverter (VSI) is presented here. The projected work investigates the Selective Harmonic Elimination (SHE) to eliminate harmonics produced by Pulse Width Modulation (PWM) inverter. The selective harmonic elimination method for three phase Voltage Source Inverter (VSI) is generally based on ideas of opposite harmonic injection. In this proposed scheme, the lower order harmonics (3rd, 5th, 7th, and 9th) are eliminated by the dominant harmonics of same order generated in opposite phase by Sinusoidal Pulse Width Modulation (SPWM) inverter and by using this scheme the Total Harmonic Distortion (THD) is reduced. Analysis of Sinusoidal Pulse Width Modulation (SPWM) technique and Selective Harmonic Elimination (SHE) is simulated using MATLAB/SIMULINK model.