Abstract

The present paper describes the selective determination of two synthetic intermediates (2,4-dichloro-6,7-dimethoxyquinazoline (IMP-1) and its derivative (IMP-2) as potential impurities in the active pharmaceutical ingredient (API)-A using two-dimensional high-performance liquid chromatography (HPLC) hyphenated via on-line solid-phase extraction (SPE) (HPLC-SPE-HPLC).Two synthetic intermediates that are potential impurities in API-A were concentrated on-line on two Shimadzu MAYI-ODS SPE columns (10mm×4.6mm I.D.) after heartcutting in 1st dimension HPLC (1st HPLC) using a Shiseido CAPCELL PAK ACR C18 column (250mm×10.0mm I.D.). Each analyte retained on these SPE columns was transferred to 2nd dimension HPLC (2nd HPLC) with a Shiseido CAPCELL PAK MG-II column (150mm×3.0mm I.D.) for further separation and was subsequently detected with high sensitivity UV. The HPLC-SPE-HPLC system achieved a stepwise downsizing in HPLC. The method was validated and found to be accurate and precise with a linear range of 0.25–250ppm of each intermediate in API-A with respect to a 500μL injection of 40mg/mL of API-A in dimethyl sulfoxide. The method was successfully applied for the determination of these impurities in API batches, and the results demonstrated the usefulness of HPLC-SPE-HPLC for the selective determination of trace impurities in APIs

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call