Abstract

A selective, sensitive, and reliable method was devised to determine concentrations of amitriptyline and its major metabolite, nortriptyline, in human plasma using high-performance liquid chromatography (HPLC) combined with UV and particle beam mass spectrometry (PBMS). Amitriptyline and nortriptyline were effectively extracted in a three-step solvent extraction procedure. Imipramine was used as the internal standard (IS). Amitriptyline, nortriptyline, and the IS were clearly separated by HPLC on a silica column with the mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear in the concentration range of 10-1000 ng/g for both compounds with UV and PBMS detections. The lower limits of detection were 5 ng/g for amitriptyline and 10 ng/g for nortriptyline with UV detection and 2 ng/g for amitriptyline and 5 ng/g for nortriptyline with PBMS detection. The absolute recoveries were 58% for amitriptyline and 47% for nortriptyline at a concentration of 50 ng/g. This method proved most useful in accurately identifying amitriptyline and nortriptyline in tissues from an autopsied individual.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.