Abstract

<span lang="EN-US">The Prototype Fast Breeder Reactor steam generators inspection system has seven modules. In this, tube locator module is a planar serial two-link robotic arm, which is used to place the eddy current probe above the steam generators tube hole in the tube sheet region. The trajectory planning of the two-link robotic arm is one of the important tasks, so the peak velocity, peak acceleration, peak jerk of various motion profiles for a given distance has to be selected properly for smooth motion and to avoid actuator saturation. The fifth-order polynomial gives lower acceleration and velocity than the jerk-limited S-curve. In this paper, the comparison of peak values of kinematic variables (velocity, acceleration, and jerk) for different motion profiles has been presented.</span>

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call