Abstract
Abstract Rust inhibitors should be selected with reference to the type of service in which they will be used. Many inhibitors which give satisfactory results under mild rusting conditions fail to provide useful protection under more severe conditions. Laboratory testing programs should be designed, therefore, to reproduce as closely as possible the conditions of actual practice. Rust inhibitor test methods are discussed in relation to three general classes of service, corresponding to flowing, static, and condensation conditions. A new rust inhibitor testing procedure, based on the Indiana Conductometric Test, provides quantitative measurements of very low corrosion rates under carefully controlled conditions. Small differences in the performance of good rust inhibitors have been detected by this method. The choice of general type of rust inhibitor (aqueous- or oil-soluble) as well as the particular compound to be used in any case, should be based on the results of selected quantitative laboratory tests, ...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.