Abstract

The energy consumption of prime motors used in oilfields is the one-third of the total energy consumption of beam pumping unit wells. In order to keep initiating and operating the prime motor smoothly and safely, its actual rated power is high much more than the needed. With the intention of improving the efficiency of the prime motor and decreasing the cost of rod-pumping, a set of rated power calculated methods and a set of matching templates was built up under the regarding conditions such as the changing rule of the system load, the heating of the prime motor and the overload torque in the initiate processing. The tested data indicated that, after replacing the prime motor with lower power, the active power, the inactive power and the suspended polished-rod load were all decreased substantially.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.