Abstract
This article deals with the problem of choosing the thickness of the heat-refl ecting screen behind the heating radiator, in which the conditions for the formation of condensate on the wall are not achieved. Based on the analysis of the results obtained, the maximum thickness of the screen is established, using the example of penofol, at the calculated temperature diff erence in the conditions of a cold fi ve-day period, and the heat losses and the economic eff ect of this energy-saving measure are determined already during the heating period. Calculations were carried out for a wall made of reinforced concrete, covered with plaster on the outside. This technique can be used for other cases of enclosing structures and various materials of the heat-refl ecting screen.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.