Abstract

This paper introduces a new lower-limb rehabilitation machine that meets the rehabilitation needs of hemiplegic patients. First, a left–right independent rotary pedal mechanism was selected to facilitate rehabilitation and adapt to the user’s physical condition. Then, a half model of the lower-limb rehabilitation machine is designed and manufactured with ergonomics in mind. As analytical tools, we combine non-negative matrix factorization and non-negative double singular value decomposition to calculate muscle synergy of the walking muscle surface electromyography (sEMG) signal, and use cosine similarity to evaluate the similarity between walking and pedaling activities. By comparing the results of the walking and pedaling experiments, the effectiveness of pedaling in gait rehabilitation is revealed. To further improve the similarity between walking and pedaling, double integration of the sEMG signal is introduced, and the relationship between load input and rotation angle is described for the first time using Fourier series. The results of the experiment confirmed that more than half of the 10 subjects performed pedaling exercises similar to walking using Fourier series loading compared to pedaling exercises with normal constant loading. This loading parameter may have the potential to improve rehabilitation efficiency for many subjects compared to the usual exercise.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call