Abstract
Based on the conducted experimental studies, the necessary parameters were selected to provide reliable testing of concrete defects. The measuring system must have: input sensitivity of the receiving electromagnetic channel of at least100 μV, the working frequency range of 1–120 kHz; the sampling frequency of 500 kHz, as well as a device that allows fast Fourier transform. The registration of the electrical response during an elastic impact should be made by a differential electric sensor, which allows measurements under conditions of external electromagnetic interference.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.