Abstract

BACKGROUND: For placement of intraradicular posts the intracanal filling material has to be removed. If drills are employed for this purpose, extra widening of the canal, incomplete cracks or root perforation are probable when inappropriate size of drill is used. OBJECTIVE: This in vitro study assessed the efficacy of radiographs taken after completion of root canal therapy in selecting the appropriate-sized Peeso reamer for post space preparation. METHODS: Canals of 53 extracted maxillary and mandibular teeth of different types were cleaned and shaped. Then with acrylic resin 3-dimensional model of the intracanal space of each tooth was fabricated. Next, all canals were filled with gutta-percha and teeth were radiographed buccolingually. Based on these radiographs two observers selected a Peeso reamer that best matched each canal’s diameter. The diameter of the selected Peeso reamer was compared to the diameter of the corresponding resin model of each canal by two independent observers and the difference was measured. The data were analyzed by paired sample t-test using SPSS version 22. RESULTS: The diameter of the selected Peeso reamers ranged from 0.21 mm smaller to 0.12 mm larger than the diameter of intracanal spaces. The difference between reamer and resin model was less than 0.1 mm in 75% of the cases. CONCLUSION: The result of this study suggests that post-operation endodontic radiographs are reliable means for selecting a size of Peeso reamer that does not encroach on dentinal wall during removal of intracanal filling material and post space preparation.