Abstract

Now, water environment in industrial zones increasingly contaminated by wastewater. Therefore, the production facilities must build preliminary processing system before discharging into the collective wastewater treatment system. The study aims to provide an optimal scenario for installation design and operate the wastewater treatment system to effectively nutrients remove. In the case study, the scenarios are simulated by the ASM2d model (Activated Sludge Model No. 2d) based on the AAO (Anaerobic, Anoxic, Aerobic/Oxic) and SBR (Sequencing Batch Reactor) system to select scenarios that have met NH4+ ≤3 mg/l, TN ≤ 5 mg/L, TP ≤ 1 mg/L associated with American and Lao standards. The results showed 269/855 scenarios were satisfactory, 16 scenarios optimized in AAO system. and 27/180 scenarios of the SBR system have been achieved, 4 scenarios achieved optimization. In the study, the optimal simulation scenario of the AAO system was more suitable than the SBR system with a total volume of 2,056 m3 and oxygen consumed 509,364 kg/day.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.