This paper presents a method for finding the optimal floor slabs according to the requirements of the Spanish Building Code (CTE), the Spanish Structural Concrete Code (EHE-08) and good building practices. This method is applied to the case of one-way floor slabs with on-site cast ribs according with the characteristics and performance parameters usually offered by firms in the industry. The initial data and the variables involved in the process cover the technical viability, sustainability and monetary cost of slabs by incorporating specific ratios to assess the suitability of each solution. The method set out here may prove helpful to construction specialists who need to select optimal-cost floor slabs with the lowest environmental impacts.

Highlights

  • Exigencias actuales en el diseño de estructuras dad de las construcciones, fomentando la innovación en los procesos constructivos y estableciendo metodologías para el control y mejora de la eficiencia energética

  • Dicha base de datos posibilita la selección de las mejores soluciones basados en criterios técnicos, económicos y sostenibles

  • Con objeto de simplificar el proceso, dentro del universo de posibles alternativas, no se han contemplado los casos formados por un vano interior o un vano aislado, pues se considera que el vano extremo es el más representativo en edificación residencial en cuanto a consumos y prestaciones del forjado

Read more

Summary

SUMMARY

This paper presents a method for finding the optimal floor slabs according to the requirements of the Spanish Building Code (CTE), the Spanish Structural Concrete Code (EHE-08) and good building practices. This method is applied to the case of one-way floor slabs with on-site cast ribs according with the characteristics and performance parameters usually offered by firms in the industry. The method set out here may prove helpful to construction specialists who need to select optimal-cost floor slabs with the lowest environmental impacts. Palabras clave: Forjado unidireccional; Keywords: One-way floor slab; stiffness; rigidez; costes; sostenibilidad.

INTRODUCCIÓN
El concepto de sostenibilidad en el diseño de estructuras
Los forjados unidireccionales
Objetivos del trabajo presentado
Definición de la geometría y materiales de cada solución
Cálculo de cada solución
Número de soluciones a estudiar
Creación de la base de datos
Interpretación de los resultados
Resultados para los forjados de 5 metros de luz
Resultados para los forjados de 6 metros de luz
CONCLUSIONES
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.