Abstract
In order to study the possibility of structural failure of high-rise composite frame-concrete tube structure under different earthquake intensity, seismic vulnerability analysis of the structure is carried out based on IDA principle, and its seismic performance is evaluated. Taking 30-storey high-mixing structure as an example, eight seismic records are selected. After amplitude modulation, non-linear dynamic time history analysis is carried out. PGA, PGV and Sa are selected as seismic intensity parameters, and the maximum inter-storey displacement angle is selected as structural performance index. IDA curve clusters are obtained. Quantile curve method is used to analyze and analyze the results. It is concluded that PGA strength index is more effective. The seismic performance of this kind of structure is evaluated effectively, and then the vulnerability curve and vulnerability matrix are obtained. The analysis results show that the hybrid structure can meet the requirements of “three-level” seismic response and has good seismic performance under 8-degree frequent, basic and rare earthquakes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.