Abstract

Earthquakes and laboratory experience show that columns with inadequate transverse reinforcement are vulnerable to damage including shear and axial load failure. To study this behavior, four full-scale columns with light transverse reinforcement were tested quasistatically under unidirectional lateral load with either constant or varying axial loads. Test results show that responses of columns with nominally identical properties vary considerably with magnitude and history of axial and lateral loads. Observed behavior is compared with expected behavior based on available analytical models. The FEMA 356 assessment model predicted the column strengths well, but underestimated the displacements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.