The article presents seismic resistance evaluation study of unreinforced brick masonry buildings. The study was carried out as part of the Ph.D. research work of the first author. As part of the study, in addition to the standard laboratory tests, a dynamic field test was carried out on single-story, single-room unreinforced masonry structure. The model structure was tested in actual ground conditions against simulated earthquake vibrations produced through controlled explosions, especially designed for this purpose. Based on masonry properties accrued from lab and field tests, finite element models of the brickwork system were also studied. Finally, the software named, “Shear Damage Index (SDI),” developed as part of this study, was used to plot contours of shear demand (shear stress) to shear capacity (shear strength) ratio on the numerical model and hence to identify potential weak zones in the model for possible strengthening of those locations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.