Abstract

The newly exposed column base (ECB) for L-shaped concrete-filled steel tube (CFST) columns investigated in this study consists of an outer base plate, a concrete cushion, and anchor bolts. Three ECB specimens of the L-shaped CFST column were tested under constant axial loading and cyclic horizontal loading to investigate their seismic behavior. The failure mode, moment versus rotation relationship, hysteretic behavior, and ultimate moment strength were analyzed. The test results indicated that the failure mode of ECB is the failure of the concrete cushion and yielding of the base plate and anchor bolts. Furthermore, a parametric analysis based on a verified finite element model was performed to investigate the influence of various parameters on the ultimate moment strength. Finally, a simplified strength model of ECB for L-shaped CFST based on the composite yielding method was proposed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.