Abstract

The force reduction factor ( R ) and its components for steel buildings are evaluated in this study. The R factor for single-degree-of-freedom models produces non-conservative designs. The global R values can be very different than the local ones. The contribution of damping to R is much more uniformly distributed and different than that of yield, implying that the latter should not be expressed in terms of viscous damping. The value of 8 specified in the codes for R is justified only for low-rise buildings and global parameters, if viscous damping is considered. If damping is not considered, this value cannot be justified in any case, a value of 6 is recommended.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.