Abstract
In several Chinese historic timber buildings, widening flaws in tenon of joints are usually a consequence of weathering and shrinkage. To investigate the impact of flaws on the seismic performance of through-tenon joints (TTJ), cyclic loading tests on four specimens were conducted. The hysteresis, skeleton, energy dissipation and stiffness experimental curves were so obtained. A finite element (FE) model to describe the behavior of such experimental specimens has been then established calibrating the mechanical properties by means of coupon tests. By comparing the numerical simulation results with the experimental results, it is concluded that this kind of damage has less impact on the mechanical performance of TTJs under negative load, while it has a greater impact under positive load. The impact was more noticeable as the length of large head of through tenon increased. The rotation capacity, stiffness and energy dissipation capacity of the damaged joints were significantly lower than the intact ones. The bearing capacity of TTJs with the damage decreased by about 32.4%–38.5%, the energy dissipation coefficient decreased by about 17%–38%, and the cumulative energy consumption decreased by 33.3%–60%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.