Abstract
This study presents the shake-table tests of a 1/5-scaled RC frame retrofitted with RC infill walls. The intensity of input ground motions increased gradually to comprehensively evaluate the structural seismic behavior. We performed a comparison of the results from the RC frame with masonry walls and that with RC walls. The results showed that the presence of RC infills effectively improved the lateral structural stiffness and loading capacity of the frames and reduced their damage and story drift. RC walls acted as the first seismic line of defense, and their failure was dominated by bending failure and concentrated on the low stories. The displacement ductility of the structure decreased with increasing stiffness of the introducing infills.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.