Abstract

AbstractSteel moment resisting frames (MRFs) are drift‐sensitive structures and their design is largely influenced by code requirements to limit the lateral displacements and to control the second order effects. Current and next generation of Eurocode 8 recommend different rules to verify the lateral rigidity and resistance of steel MRFs that lead to structures that are substantially different in terms of size of members and overall performance. In order to investigate the influence of the design rules on the seismic behaviour of ductile steel MRFs a parametric numerical study was carried out on 48 structures designed according to Eurocodes as well as US codes, the latter analysed as benchmark, varying the number of storeys, moment resisting spans and seismic intensity. The results of non‐linear static and dynamic analyses show that the structures complaint with current Eurocode 8 are the most expensive and characterised by the greater lateral rigidity and resistance, while MRFs designed in accordance with ASCE7 rules have the smaller profiles and the lower overstrength. The frames designed with rules of the latest version of next generation of Eurocode 8 have an intermediate behaviour even if closer to ASCE7‐compliant structures. These results are also confirmed by the probability of collapse that is smaller than the minimum value specified by EN1990 for the considered consequence class of the examined buildings.