Abstract

This research paper describes the results of analysis of the seismic behavior of a thirty story steel building with and without damper under different earthquake acceleration signals. The proposed procedure placed the various types of damper like friction damper, bilinear damper and exponential damper on the top three floors of the building. The study compares the different performances such as the joint displacement, joint acceleration, the base force of structure with and without damper for a thirty-story steel building using ETAB2015. The study further performs time history analysis for different seismic accelerograms to observe the actual time domain responses of the structure. Linear time-history analysis on this steel building structure indicates that maximum displacement, maximum base force, and maximum acceleration effectively reduce in the presence of damper at top three floors of the building.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.