Abstract
AbstractThis paper presents the experimental investigation of two brace middle connections: 1) using a slotted tube knife‐plate connection (STKPC), and 2) a bolted sandwich plate connection (BSPC). The STKPC consists of a gusset plate slotted through the continuous brace and welded to discontinuous braces. The BSPC consists of two cover plates and four U‐shaped plates connecting the discontinuous braces using bolts. The two cover plates pass on either side of the continuous brace and are bolted to the U‐shaped plates. These connections are used to join the discontinuous braces in steel concentrically braced frames (CBFs) configured with X‐bracing. These connections were tested as part of a full‐scale CBF using quasi‐static testing. In both specimens, seismic energy dissipated through yielding and buckling of the braces. However, in the specimen with STKPC, axial deformation is concentrated in a single discontinuous brace, which led to local buckling at mid‐length and subsequent fracture. In contrast, the BSPC is able to better distribute axial deformation between the two discontinuous braces delaying local buckling. Moreover, the measured buckling capacity of braces when using the BSPC matches well the expected compressive resistance calculated using an effective length factor K = 0.45.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.