Abstract

This paper proposes a new moment-resisting connection known as a through rib stiffener beam connection, which is directly passed through a pre-slotted circular column with concrete infill. Four half-scale cruciform specimens with orthogonal beams were tested under cyclic loading. The failure modes, hysteretic performance, rotation capacity, strength and stiffness degradation, ductility, and energy dissipation of the connections were analysed. The effect of different parameters, such as through rib stiffener and beam section size, on the connection performance was investigated. The experimental results indicated that the new through rib stiffener beam connected with circular columns exhibited a large hysteretic enclosed area, good ductility, and excellent energy dissipation. The results proved that the proposed connection satisfies the seismic provisions and ductility design requirements for it to be utilized as moment-resisting frames in a seismically active area.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.