Abstract

This study used test frames were purposely detailed and constructed with observed deficiencies in investigated dormitory buildings of Turkey. In this study, four reinforced concrete frames were produced two storeys, one bay and 3D in 1/6 geometric scale was tested. Since the studied frame was the external frame of the structure, brick infill wall with a window opening was also included. The first specimen was the reference specimen and contained no strengthening and no brick wall. The second specimen was contained brick wall. The third specimen was strengthened with internal steel panel. Finally fourth specimen’s was strengthened with infilled RC shear wall. The test specimens were subjected to reversed cyclic quasi-static lateral loading. Strength of the test specimens were measured and compared. Test results indicated that the strengthened specimens displayed significantly higher lateral strength than the reference specimen considerably.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.