Abstract

The building-damper system designed by a seismic code is usually considered to be able to withstand the attack of strong earthquakes. However, near-fault earthquakes, especially those with the forward-directivity effect, might cause early and unexpected failure of code-designed dampers and consequent severe structural damage. In this paper, by taking into account near-fault earthquakes, seismic performance of the building-damper system and damper failure’s influence are evaluated systematically. A 9-storey steel building is designed by the Chinese seismic code as the benchmark model, and five typical dampers, including buckling-restrained brace damper (BRB), friction damper (FD), self-centering damper (SCD), viscous damper (VD), and viscoelastic damper (VED), are adopted. It was found that the building-damper systems show a large response and possible damper failure under the near-fault earthquake excitations. Then, the influence of damper failure is investigated, which reveals that damper failure would significantly affect seismic performance of the building-damper system, especially for the building-SCD system. Subsequently, by introducing the artificial near-fault earthquake excitation, the influences of different pulse parameters, such as pulse velocity amplitude, pulse period, and the number of significant pulses, are studied. It shows that the pulse velocity amplitude and pulse period obviously affect the seismic performance, while the number of significant pulses presents little influence.

Highlights

  • Building-Damper SystemsE finite element model was constructed in OpenSees, and all the beam and column components were modeled by the dispBeamColumn element with the fiber section [43]

  • Academic Editor: Ivo Calio e building-damper system designed by a seismic code is usually considered to be able to withstand the attack of strong earthquakes

  • A 9-storey steel building is designed by the Chinese seismic code as the benchmark model, and five typical dampers, including buckling-restrained brace damper (BRB), friction damper (FD), self-centering damper (SCD), viscous damper (VD), and viscoelastic damper (VED), are adopted

Read more

Summary

Building-Damper Systems

E finite element model was constructed in OpenSees, and all the beam and column components were modeled by the dispBeamColumn element with the fiber section [43]. E dampers were installed on each storey of the 9storey building as shown in Figure 1 and modeled by the twonode-link element in OpenSees. Constitutive model of steel k0: initial elastic tangent; b: ratio between postyield tangent and initial elastic tangent; Fy: yield strength

Near-Fault Earthquake Excitations
Influence of the Forward-Directivity Effect
Seismic Performance of BuildingDamper System
Influence of Pulse Parameters
Findings
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.