A seismic performance of full-scale precast reinforced concrete beam-column corner joint with corbel was examined in the laboratory. The precast beam-column joint designed using BS8110:1:1997 was tested under lateral cyclic loading up to +1.5% drift. Displacement ductility of precast beam-column joint with corbel was determined. The visual observation showed that the damage occurred at the corbel of beam-column joint. Major cracks were also observed at the cast-in-place area above the joint area. In this paper, the damage state of the specimen is categorized in accordance to HAZUS®99 and the vulnerability of the specimen was assessed using fragility curve.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.